Conventional mining

Built to last in the toughest conditions

Bergstrom HVAC units deliver unmatched reliability and performance. Our custom engineering services and global support ensure you get the exact solution you need.

Products: F-Series

The F-Series is our line of filter/pressurizers. In this series you can find anything from stand-alone self-cleaning filter packages to simple canister-like add-on filters. We’ve designed the series using some of the industry’s most efficient filter media available and with efficiency ratings of 99% on particle sizes 0.5 microns and above.

Model Specifications: FVF120 120V 
Voltage120V
Amps3 AMPS @ 120 V.A.C.
20 AMPS @ 24 V.D.C.
Maximum air flow365 SCFM
(620 m3/hr)
Dimensions
(L x W x H)
24in x 34.37in x 35.56in
(609.6mm x 873mm x
903.2mm)
Weight285 lb (129,3 kg)
Mounting PositionFoot

Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Model Specifications:FVV50 12VFVV50 24V
Voltage12V24V
Amps10 AMPS @ 12 V.D.C5 AMPs @ V.D.C.
Maximum air flow85 SCFM
(144 m3/hr)
85 SCFM
(144 m3/hr)
Dimensions
(L x W x H)
30.84in x 9.07in x 19.1in
(783mm x 230mm x 485mm)
30.84in x 9.07in x 19.1in
(783mm x 230mm x 485mm)
Weight17 lb
(7,7 kg)
17 lb
(7,7 kg)
Mounting PositionFootFoot

Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators

Model Specifications:FVV650 12VFVV60 24V
Voltage12V24V
Amps10 AMPS @ 12 V.D.C5 AMPs @ V.D.C.
Maximum air flow170 SCFM
(289 m3/hr)
170 SCFM
(289 m3/hr)
Dimensions
(L x W x H)
30.84in x 9.07in x 19.1in
(783mm x 230mm x 485mm)
30.84in x 9.07in x 19.1in
(783mm x 230mm x 485mm)
Weight21 lb
(9,5 kg)
21 lb
(9,5 kg)
Mounting PositionFootFoot

Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Model Specifications:FVV150 12VFVV150 24V
Voltage12V24V
Amps14 AMPS @ 12 V.D.C.7 AMPS @ 24 V.D.C.
Maximum air flow315 SCFM
(535 m3/hr)
315 SCFM
(535 m3/hr)
Dimensions
(L x W x H)
33.84in x 18.38in x 25.44in
(859.5mm x 466.9mm x
646.2mm)
33.84in x 18.38in x 25.44in
(859.5mm x 466.9mm x
646.2mm)
Weight88.2 lb
(40 kg)
88.2 lb
(40 kg)
Mounting PositionFootFoot

Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Model Specifications:FVW100 120VFVW100 24V
Voltage12V24V
Amps3 AMPS @ 120 V.A.C7 AMPS @ 24 V.D.C.
Maximum air flow365 SCFM
(620 m3/hr)
365 SCFM
(620 m3/hr)
Dimensions
(L x W x H)
19.75in x 28.7in x 11.38in
(501.7mm x 729mm x
289mm)
19.75in x 28.7in x 11.38in
(501.7mm x 729mm x
289mm)
Weight100 lb
(45,5 kg)
100 lb
(45,5 kg)
Mounting PositionWallWall

Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Products: M-Series

The multipurpose M-Series is designed to be used on larger cabs where 3-phase electrical Capacity is available, such as draglines, drills, crane cabs and shovels. These are the largest systems in the Bergstrom line and are available in capacities of 18,000 BTU/hr to 54,000 BTU/hr. Various voltages are available.

Model Specifications: MPV5 
Capacity*Cooling: 18,000 BTU/hr (5,3 kW)
Heating: 34,000 BTU/hr (10,0 kW)
Amps20 AMPS @ 460/3/60
Maximum air flowHigh: 600 SCFM (1,019 m3/hr)
Low: 500 SCFM (850 m3/hr)
Dimensions
(L x W x H)
48in x 32.8in x 23.66in
(1,219mm x 833mm x 601mm)
Weight540 lb
(244,9 kg)
Mounting PositionRooftop, Walkway or Deck

(*) System cooling capacity is based on system component-calculated capacities in accordance with IMACA 200 standard test conditions: inddor 80ºF DB/67ºF WB with outdoor 110ºF DB/60ºF WB. Heating capacity is at rated voltage in accordance with SAEJ638. Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Product name: MPV9 HVAC System    
Heating Capacity 41,000 BTU/hr (12,0 kw)
Cooling Capacity 31,000 BTU/hr (8,9 kw)
Maximum Air Flow High: 1.300 SCFM (2,209 m3/hr) Low: 870 SCFM (1,478 m3/hr)
Condenser Dimensions (L x W x H) 47.48in x 62.72in x 32.75in (1,206mm x 1,593mm x 832mm)
Weight 1,100 lb (499 kg)
Mounting Position Rooftop, Walkway or Deck
Model Specifications:MPV5
Heating Stages2
Pressurization120 CFM (56 l/s)
Controls110 VAC
Motor ProtectionThermal Overload
Circuit Breaker
Compressor Capacity ControlNone
Condenser Fan1-Speed
Refrigerant MeteringTXV
Thermostat – Electronic
5-stage
Standard

Product name:MPV11 HVAC System    
Heating Capacity61,000 BTU/hr (18,0 kw)
Cooling Capacity38,000 BTU/hr (11,0 kw)
Maximum Air FlowHigh: 1.478 SCFM (2,209 m3/hr)
Low: 870 SCFM (1,1,300 m3/hr)
Condenser
Dimensions
(L x W x H)
375.5in x 29.0in x 33.0in
(952.2mm x 736.6mm x 832mm)
Condenser Weight575 lb (261 kg)
Evaporator
Dimensions
(L x W x H)
37.5in x 34.0in x 37.75in
(952.5mm x 863.6mm x
958.9mm)
Evaporator Weight465 lb (211 kg)

Model Specifications:  BES2400  
Capacity* Cold: 24,000 BTU/hr (7 kW)
Hot: 20,450 BTU/hr (6 kW)
Amps 40 AMPS @ 24 V. D. C.
Maximum air flow 600 SCFM (1,019 m3/hr)
Dimensions
(L x W x H)
43.31n x 31.65in x 15.33in
(1,100mm x 8043mm x 389.4mm)
Weight 208 lb
(110 kg)
Mounting Position Rooftop

(*) System cooling capacity is based on system component-calculated capacities in accordance with IMACA 200 standard test conditions: inddor 80ºF DB/67ºF WB with outdoor 110ºF DB/60ºF WB. Heating capacity is at rated voltage in accordance with SAEJ638. Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

Model Specifications: BES3000 
Capacity*30,000 BTU/hr (8,8 kW)
Amps35 AMPS @ 230/1/60
Maximum air flow600 SCFM (1019 m3/hr)
Dimensions
(L x W x H)
66.5n x 28.3in x 22.8in
(1,689mm x 719mm x 579mm)
Weight480 lb (218 kg)
Mounting Position 

(*) System cooling capacity is based on system component-calculated capacities in accordance with IMACA 200 standard test conditions: inddor 80ºF DB/67ºF WB with outdoor 110ºF DB/60ºF WB. Heating capacity is at rated voltage in accordance with SAEJ638. Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators.

ENGINEERING SOLUTIONS TAILORED TO YOUR NEEDS

Discover how Bergstrom is leading the way toward a sustainable future with our complete range of air and liquid cooling systems.

mining

Products: T-Series

Our T-Series, or tractor series, is designed to be used on cabs of various rubber-tired or tracked vehicles; such as haul trucks, small drills and others. The systems are generally 12 or 24 V.D.C. and typically require a remote engine-driven compressor.

ModelTBV6 12VTBV6 24V
Voltage12V24V
Dimensions
(L x W x H)
32.88in x 12.63in x 13.38in (835mm x 321mm x 340mm)32.88n x 12.63in x 13.38in
(835mm x 321mm x 340mm)
Weight100 lb
(45,4 kg)
100 lb
(45,4 kg
Mounting
Position
Rooftop or DeckRooftop or Deck

ModelTCR6 12VTCR6 24V
Voltage12V24V
CapacityFor use up to 22,000 BTU/hr
(6,4 kW
For use up to 22,000 BTU/hr
(6,4 kW)
Maximum
air flow
2,400 SCFM
(4,078 m3/hr)
2,400 SCFM
(4,078 m3/hr)
Dimensions
(L x W x H)
32.56n x 15.21in x 13.18in (827mm x 386mm x 335mm)32.88n x 12.63in x 13.38in
(835mm x 321mm x 340mm)
Weight40 lb
(18,1 kg)
40 lb
(18,1 kg)
Mounting
Position
Rooftop or DeckRooftop or Deck

Model Specifications:TDR5 HVAC System
Voltage24V
Heating Capacity35,000 BTU/hr (10,0 kW)
Cooling Capacity18,000 BTU/hr (5,2 kw)
Maximum Air FlowHigh: 400 SCFM (680 m3/hr)
Medium: 350 SCFM (595 m3/hr)
Low: 300 SCFM (510 m3/hr)
Dimensions
(L x W x H)
40.39in x 39.22in x 10.55in
(1,026mm x 996mm x 268mm)
Weight150 lb (68,0 kg)
Mounting PositionRooftop

Model Specifications: TPR6 AC System
Heating Capacity40,000 BTU/hr (11,7 kW)
Cooling Capacity20,473 BTU/hr (6,0 kw)
Maximum Air Flow450 SCFM (764.6 m3/hr)
Dimensions
(L x W x H)
58.72in x 40.92in x 13.39in
(1491.39mm x 1,039.4mm x 340mm)
Weight400 lb (181,4 kg)
Mounting PositionRooftop

Model Specifications: TPW5 24V 
Capacity*Cold: 18,000 BTU/hr (5,3 kW)
Hot: 40,000 BTU/hr (11,7 kW)
Amps25 AMPS @ 24 V.D.C.
Maximum air flow450 SCFM
(765 m3/hr)
Dimensions
(L x W x H)
36.67in x 19.2in x 25.7in
(931.4mm x 487.7mm x 652.8mm)
Weight375 lb
(170 kg)
Mounting PositionDeck

(*) System cooling capacity is based on system component-calculated capacities in accordance with IMACA 200 standard test conditions: 100ºF and 81ºF FDB/67ºF FWB (38ºC and 27/19ºC) return air. Unless otherwise stated, performance measurements are conducted in accordance with SAE J638 for heaters and IMACA 200 for evaporators

If the solution you are looking for does not exist or if you want more information about a product, please contact us.

Leave your details in the form below, and we will contact you to create together the air conditioning solution perfectly adapted to your needs.

Scroll to Top
Profesional
Caravaning
certificados-de-calidad-imagen

Certificaciones
de Calidad

Descarga aquí nuestros certificados de calidad:
certificados-de-calidad-imagen

QUALITY
CERTIFICATIONS

Download our quality certificates here:

ENVIRONMENTAL CERTIFICATIONS

Download our Annual Report here: